Useful Information On AFM Probes

By Charles Edwards


The field of scanning has exploded exclusively beyond the use of interatomic forces to image topographies on a nano-meter scale. The invention has made this a reality of AFM probes which can provide a measure for intermolecular forces. It is a scientifically tantalizing invention which made it possible for scientists to see atoms. The deflator uses atomic forces to map a tipped sample interaction.

The Atomic Force Microscopy techniques were developed to overcome a prime drawback associated with the previous versions, the STM. The latter had only the ability to image conducting or semiconducting surface topologies. The introduction has channeled a heap of benefits since it can image almost any surface type, including ceramics, polymers, glass, composites, and biological samples.

The nano-structure comprises of a cantilever detector which is position sensitive. The cantilever is micro-fabricated together with its tip. It functions by imaging the forces tracked between the tip and sample surface under investigation. The finding figures are not the final results; thus, one has to compute the statistics recorded. However, a researcher is also tasked with the duty of maintaining a constant lever stiffness to improve the accuracy of projected results.

The AFM probe is essentially used to scan a selected surface using the cantilever tip which is set to travel near the surface under-regulated velocities. This creates a force which is trapped between the tip and surface in question. It causes a deflection on the lever as stipulated by Hooke law. The imaging capability is a variable of prevailing situation and the type of sample under study. One can make use of improved deflectors when carrying out specialized experiments.

The microscopy operates under two basic modes, namely, the contact method and non-contact method. Their difference arises whether the cantilever will vibrate during operation or not. The contact mode entails the use of low stiffness cantilevers, which allows strong attractive to pull the tips towards the surface. They are also effective in eliminating noise and drift. In the non-contact mode, the tip does not come into contact with the sample surface, and it only vibrates slightly beyond it resonance frequency.

Additionally, the Atomic Force Microscopy is an effective device which is widely used in faculty of scientific research to measure small sample units with a high level of accuracy. Its operation ability does not necessitate the presence of a vacuum or sample. The ideology of vacuum medium is effectively demonstrated by researchers using atomic resolution. Its accuracy makes it the most powerful nanometer scaled equipment.

However, the device is also attributed by various downsides. The major drawback is its single scanning image size, which is very small. The image size is usually in micrometers, compared with the scanning of the electron microscope, which produces an image size in millimeters. It also has a relatively sluggish scan time, which can cause thermal drift on a sample surface.

Therefore, as the field of technology matures, the researchers are requiring advanced signal-to-noise ratio and facilities with decreased thermal drift. This will enhance the detection and the controllability of tip-sample forces. Thus, developers are put to task to achieve the improvements for better research activities.